All standards · RED

EN 300 220-2: short range devices from 25 MHz to 1,000 MHz.

Summary
  • EN 300 220-2 V3.3.1 has been listed under Article 3(2) of the Radio Equipment Directive since 11 December 2025. The previous edition V3.1.1 remains listed until 10 June 2027.Commission RED list, generated 7 Sep 2026; Implementing Decision (EU) 2025/2499, Art. 2 and Annex
  • The standard covers short range devices of the non-specific category between 25 MHz and 1,000 MHz with up to 500 mW e.r.p., such as 433 MHz and 868 MHz remote controls, sensors, LoRa and EnOcean devices.cl. 1, Table 4; testxchange radio map
  • From 11 June 2027, V3.1.1 no longer gives a presumption of conformity for units placed on the market. Version V3.2.1 has never been listed, so a declaration of conformity that cites only V3.2.1 rests Article 3(2) on no listed harmonised standard.RED Art. 16, Art. 17(4); Implementing Decision (EU) 2025/2499
  • We plan and carry out the radio test to V3.3.1, and we review your declaration of conformity.
Request a quote →You receive an offer within 2 working days.

EN 300 220-2 is the harmonised standard for short range devices of the non-specific category that operate between 25 MHz and 1,000 MHz. The non-specific category comprises radio devices of any application that meet the technical conditions of a frequency band, for example telemetry, telecommand, alarms and data transmission in general. Products with 433 MHz or 868 MHz radio are tested to this standard for Article 3(2) of the Radio Equipment Directive, which requires radio equipment to use the radio spectrum effectively and to support its efficient use.

Listed edition
EN 300 220-2 V3.1.1
Presumption of conformity from 10 Mar 2017
no presumption from 11 Jun 2027, successor EN 300 220-2 V3.3.1
EN 300 220-2 V3.3.1
Presumption of conformity from 11 Dec 2025
Listed under
Radio Equipment Directive 2014/53/EU
Radio types
Short-range radio from 25 MHz to 1 GHz (proprietary protocols, remote controls, sensors)
LoRa / LoRaWAN (868 MHz in the EU)
EnOcean (868 MHz in the EU)

Scope of the standard

  • The standard defines the technical requirements for short range devices of the non-specific category between 25 MHz and 1,000 MHz, the limits they must meet and the methods by which they are measured. These devices transmit with up to 500 mW effective radiated power (e.r.p.) and may be used indoors or outdoors.cl. 1
  • Table 4 of the standard lists the permitted frequency bands with their maximum power, their channel access rules and their maximum bandwidth. For example, the band 433.050 MHz to 434.790 MHz allows 10 mW e.r.p. at a duty cycle of at most 10 %. Most sub-bands between 863 MHz and 870 MHz allow 25 mW e.r.p. with a duty cycle of at most 0.1 % or 1 %, or with polite spectrum access instead. The band 869.400 MHz to 869.650 MHz allows 500 mW e.r.p. with a duty cycle of at most 10 % or with polite spectrum access.cl. 4.2.4, Table 4
  • Equipment must meet all parameters of the row of Table 4 for the band in which it operates. Equipment that uses the parameters of a national radio interface instead of the EU frequency plan does not obtain a presumption of conformity with Article 3(2) from the standard, even though the standard is listed.cl. 4.2.2, note 2
  • Separate parts of the standard series cover specific applications. EN 300 220-3-1 covers social alarms on 869.200 MHz to 869.250 MHz, EN 300 220-3-2 covers wireless alarms in designated bands, and EN 300 220-4 covers metering devices on 169.400 MHz to 169.475 MHz. All three parts are listed under the Radio Equipment Directive.Commission RED list, generated 7 Sep 2026; testxchange radio map

Which edition is listed in the Official Journal

  • Under the Radio Equipment Directive, the EU lists EN 300 220-2 V3.3.1. This edition has conferred a presumption of conformity since 11 December 2025, the date on which Implementing Decision (EU) 2025/2499 was published.Commission RED list, generated 7 Sep 2026; Implementing Decision (EU) 2025/2499, Art. 2 and Annex
  • The previous edition V3.1.1 has been listed since 10 March 2017. Implementing Decision (EU) 2025/2499 deletes its reference with effect from 11 June 2027, so V3.1.1 confers a presumption of conformity until 10 June 2027.Commission RED list, generated 7 Sep 2026 (OJ C 76); Implementing Decision (EU) 2025/2499, Art. 2 and Annex
  • ETSI published version V3.2.1 in June 2018. The reference of V3.2.1 has never been published in the Official Journal, so V3.2.1 does not confer a presumption of conformity.Commission RED list, generated 7 Sep 2026; EN 300 220-2 V3.3.1, History
  • Each unit counts on its own. Units placed on the market up to 10 June 2027 on the basis of V3.1.1 may still be made available along the delivery chain afterwards. Units placed on the market from 11 June 2027 no longer obtain a presumption of conformity from V3.1.1.Commission Blue Guide 2022, section 2.3

Which edition does your declaration of conformity cite?

  • In November 2026, testxchange reviewed 112 publicly available EU declarations of conformity of radio products from manufacturers in Germany, Austria and Switzerland. 16 of these declarations cite EN 300 220-2, and none of these 16 declarations cites V3.3.1, the edition listed since 11 December 2025. 9 declarations cite V3.1.1, which gives no presumption of conformity from 11 June 2027; one of them cites it through its German edition DIN EN 300220-2:2017-05, and one also cites the older version V2.4.1. 7 declarations cite V3.2.1, a version that ETSI published in 2018 and that has never been listed.testxchange review of public declarations of conformity, November 2026 (rules engine)
  • If your declaration of conformity cites V3.1.1, it gives a presumption of conformity for units placed on the market up to 10 June 2027. For units placed on the market from 11 June 2027, the product needs an assessment against V3.3.1 and an updated declaration, or the involvement of a notified body.RED Art. 10(5), Art. 17(4); Implementing Decision (EU) 2025/2499, Art. 2 and Annex
  • If your declaration of conformity cites V3.2.1, compliance with Article 3(2) rests on no listed harmonised standard. In that case, a notified body is required for EU-type examination (Annex III) or full quality assurance (Annex IV), unless the product passes a delta test to V3.3.1 and the declaration is updated.RED Art. 16, Art. 17(4)
  • If your declaration cites V3.1.1 or V3.2.1, we carry out the delta test to V3.3.1 and specify which tests must be repeated. V3.3.1 contains receiver requirements and timing tests for polite spectrum access that the earlier editions did not contain for all equipment.EN 300 220-2 V3.3.1, Introduction and Annex K
  • If your declaration of conformity names EN 300 220-2 without a version number, it does not meet Annex VI point 6, which requires the version of each standard applied, and the presumption of conformity cannot be verified. If the product meets a listed edition, it is sufficient to name this edition.RED Annex VI point 6
  • Please submit your declaration of conformity to us. We review the declaration against the listed editions and specify any changes that are required.
Request a review of your declaration →You receive a written assessment of your declaration of conformity.

Scope of testing

EN 300 220-2 V3.3.1 sets the following requirements. Which of them apply depends on the frequency band, the width of the operating channel, the channel access mechanism and the power supply of the product.

  • The unwanted emissions in the spurious domain are measured for all equipment, in transmit mode and in all other modes.cl. 4.3.1
  • The effective radiated power must not exceed the value that Table 4 permits for the band. In the bands with a power spectral density limit, the power spectral density is also measured.cl. 4.4.1, 4.4.2
  • The duty cycle is measured for all transmitters, except for equipment that uses polite spectrum access in the bands for which Table 4 allows it.cl. 4.4.3
  • The occupied bandwidth and the frequency stability of the transmitter are measured as two separate requirements.cl. 4.4.4, 4.4.5
  • For operating channels wider than 25 kHz, the out-of-band emissions are measured; for channels of 25 kHz or less, the adjacent channel power is measured instead.cl. 4.4.6, 4.4.7
  • The spectrum mask at the edges of the permitted band and the transient power when the transmitter switches on and off are measured for all transmitters.cl. 4.4.8, 4.4.9
  • Battery-powered equipment is tested for its behaviour at low supply voltage. Frequency hopping equipment, and equipment in bands with limits on transmit and pause times, are subject to further requirements.cl. 4.4.10, 4.4.11, 4.4.12
  • For all receivers, the sensitivity, the dynamic range, the blocking and the spurious response rejection are tested. In the channelised bands, the adjacent channel selectivity and the intermodulation rejection are also tested.cl. 4.5.1 to 4.5.6
  • Equipment that uses polite spectrum access is tested for its clear channel assessment threshold and its timing parameters. The standard requires, for example, a listening time of at least 160 µs before each transmission and a pause of at least 100 ms on the same frequency after each transmission.cl. 4.6.2, 4.6.3, Table 18

What changed from V3.1.1 to V3.3.1

A test report to V3.1.1 does not cover every requirement of V3.3.1. According to the standard itself, V3.3.1 introduces the following changes.

  • The operating channel is defined for all equipment, and the maximum occupied bandwidth is now split into a bandwidth requirement and a frequency stability requirement.Introduction; Annex K
  • The out-of-band mask is split into a mask for the operating channel and a mask for the edges of the permitted band, and the adjacent channel power limits were reviewed.Introduction
  • New receiver requirements were added, which now apply to all equipment of the non-specific category, with limits adapted to this category. Tests of the timing of polite spectrum access and temperature categories for the extreme test conditions were also added.Introduction; Annex K

Required information

We require the following information in order to plan and carry out the test. The standard lists these properties of the equipment in a form that becomes part of the test report. Please send us the information that is available. We review the information and follow up with specific questions.

  • The permitted frequency bands, the nominal operating frequencies and the operating channels, and for frequency agile or hopping equipment the lowest and highest operating frequency.Annex G
  • The local oscillator and intermediate frequencies of the receiver, and the antenna gain for equipment with an external antenna.Annex G
  • A description of the test signals that represent the intended use, and the information whether the equipment can transmit an unmodulated carrier.Annex G
  • The channel access mechanism (duty cycle, or listen before talk with adaptive frequency agility) and, for polite spectrum access, the listening time; for frequency hopping equipment, the hopping channels and the dwell time.Annex G
  • The extreme temperature category (indoor, indoor extended, outdoor, outdoor extended or automotive) and the nominal supply voltages with the upper and lower limits of the intended use.Annex G

Frequently asked questions

Which edition of EN 300 220-2 is harmonised?

EN 300 220-2 V3.3.1 has been listed in the Official Journal since 11 December 2025. The previous edition V3.1.1 remains listed until 10 June 2027 and gives no presumption of conformity from 11 June 2027.

Commission RED list, generated 7 Sep 2026; Implementing Decision (EU) 2025/2499, Art. 2 and Annex

Until when may EN 300 220-2 V3.1.1 be applied?

EN 300 220-2 V3.1.1 confers a presumption of conformity until 10 June 2027. Units placed on the market from 11 June 2027 require V3.3.1 or a notified body for Article 3(2).

Implementing Decision (EU) 2025/2499, Art. 2 and Annex; RED Art. 17(4)

Is EN 300 220-2 V3.2.1 harmonised?

EN 300 220-2 V3.2.1 is not harmonised. ETSI published V3.2.1 in June 2018, but its reference has never been published in the Official Journal, so it gives no presumption of conformity.

Commission RED list, generated 7 Sep 2026; EN 300 220-2 V3.3.1, History

How many declarations of conformity cite the listed edition V3.3.1 of EN 300 220-2?

In November 2026, testxchange reviewed 112 publicly available EU declarations of conformity of radio products from manufacturers in Germany, Austria and Switzerland. 16 of these declarations cite EN 300 220-2, and none of these 16 declarations cites V3.3.1, the edition listed since 11 December 2025. 9 declarations cite V3.1.1, which gives no presumption of conformity from 11 June 2027; one of them cites it through its German edition DIN EN 300220-2:2017-05, and one also cites the older version V2.4.1. 7 declarations cite V3.2.1, a version that ETSI published in 2018 and that has never been listed.

testxchange review of public declarations of conformity, November 2026 (rules engine)

Which standard applies to LoRa devices at 868 MHz?

LoRa and LoRaWAN devices at 868 MHz are tested to EN 300 220-2 for Article 3(2) of the Radio Equipment Directive. For EMC under Article 3(1)(b), they are tested to EN 301 489-3 together with EN 301 489-1.

testxchange radio map; EN 300 220-2 V3.3.1 cl. 1

Which EMC standard applies together with EN 300 220-2?

EN 301 489-3, applied together with the common part EN 301 489-1, is the EMC standard for short range devices under Article 3(1)(b) of the Radio Equipment Directive. EN 301 489-3 V2.3.2 has been listed since 15 May 2025.

testxchange radio map; Commission RED list, generated 7 Sep 2026

What is polite spectrum access in EN 300 220-2?

With polite spectrum access, the device listens on the channel before it transmits and transmits only when the channel is free. In several bands between 863 MHz and 870 MHz, polite spectrum access may replace the duty cycle limit, and its threshold and timing parameters are then tested.

EN 300 220-2 V3.3.1 cl. 4.4.3.1, 4.6

Sources

Malte Zur
Your contact

Malte Zur

Founder and CEO, testxchange

I answer your questions about standards, test plans and offers.

standards@testxchange.com

Get a quote for your product test

Describe your product. We plan the tests, carry them out and deliver the test report.