EN 300 220-2 is the harmonised standard for short range devices of the non-specific category that operate between 25 MHz and 1,000 MHz. The non-specific category comprises radio devices of any application that meet the technical conditions of a frequency band, for example telemetry, telecommand, alarms and data transmission in general. Products with 433 MHz or 868 MHz radio are tested to this standard for Article 3(2) of the Radio Equipment Directive, which requires radio equipment to use the radio spectrum effectively and to support its efficient use.
EN 300 220-2 V3.3.1 sets the following requirements. Which of them apply depends on the frequency band, the width of the operating channel, the channel access mechanism and the power supply of the product.
A test report to V3.1.1 does not cover every requirement of V3.3.1. According to the standard itself, V3.3.1 introduces the following changes.
We require the following information in order to plan and carry out the test. The standard lists these properties of the equipment in a form that becomes part of the test report. Please send us the information that is available. We review the information and follow up with specific questions.
EN 300 220-2 V3.3.1 has been listed in the Official Journal since 11 December 2025. The previous edition V3.1.1 remains listed until 10 June 2027 and gives no presumption of conformity from 11 June 2027.
Commission RED list, generated 7 Sep 2026; Implementing Decision (EU) 2025/2499, Art. 2 and AnnexEN 300 220-2 V3.1.1 confers a presumption of conformity until 10 June 2027. Units placed on the market from 11 June 2027 require V3.3.1 or a notified body for Article 3(2).
Implementing Decision (EU) 2025/2499, Art. 2 and Annex; RED Art. 17(4)EN 300 220-2 V3.2.1 is not harmonised. ETSI published V3.2.1 in June 2018, but its reference has never been published in the Official Journal, so it gives no presumption of conformity.
Commission RED list, generated 7 Sep 2026; EN 300 220-2 V3.3.1, HistoryIn November 2026, testxchange reviewed 112 publicly available EU declarations of conformity of radio products from manufacturers in Germany, Austria and Switzerland. 16 of these declarations cite EN 300 220-2, and none of these 16 declarations cites V3.3.1, the edition listed since 11 December 2025. 9 declarations cite V3.1.1, which gives no presumption of conformity from 11 June 2027; one of them cites it through its German edition DIN EN 300220-2:2017-05, and one also cites the older version V2.4.1. 7 declarations cite V3.2.1, a version that ETSI published in 2018 and that has never been listed.
testxchange review of public declarations of conformity, November 2026 (rules engine)LoRa and LoRaWAN devices at 868 MHz are tested to EN 300 220-2 for Article 3(2) of the Radio Equipment Directive. For EMC under Article 3(1)(b), they are tested to EN 301 489-3 together with EN 301 489-1.
testxchange radio map; EN 300 220-2 V3.3.1 cl. 1EN 301 489-3, applied together with the common part EN 301 489-1, is the EMC standard for short range devices under Article 3(1)(b) of the Radio Equipment Directive. EN 301 489-3 V2.3.2 has been listed since 15 May 2025.
testxchange radio map; Commission RED list, generated 7 Sep 2026With polite spectrum access, the device listens on the channel before it transmits and transmits only when the channel is free. In several bands between 863 MHz and 870 MHz, polite spectrum access may replace the duty cycle limit, and its threshold and timing parameters are then tested.
EN 300 220-2 V3.3.1 cl. 4.4.3.1, 4.6Malte Zur
Founder and CEO, testxchange
I answer your questions about standards, test plans and offers.
Describe your product. We plan the tests, carry them out and deliver the test report.